本文

CX-One Ver.2 各ソフトウェア
更新内容詳細

Change history of Common Module

[Auto Update System Upgraded]

  • Auto update system has been upgraded to improve the response performance and usability.
    To update the auto update system, install this update. It will be updated at the next startup.

- :Version V2.* → CX-One Version 2 Auto-update (August 2009)

Improved functions
  • Fixed the comments that are displayed in the I/O table of CJ(S) 1W-CRM21.

- :Version V2.* → CX-One Version 2 Auto-update (June 2009)

New functions

[CPS]

  • Added the following files
    CPS_CJ1W-AD042_Ver1_0.xml
    CPS_CJ1W-DA042V_Ver1_0.xml
    CPS_CJ1W-SPU01_Ver2_1.xml
    CPS_CS1W-SPU01_Ver2_1.xml
    CPS_CS1W-SPU02_Ver2_1.xml

- :Version V2.* → CX-One Version 2 Auto-update (April 2009)

New functions

[Support of New Types]

  • Ethernet units for CS/CJ-series PLCs are suppoerted.
    CS1W-ETN21 Unit Ver.1.5 and CJ1W-ETN21 unit Ver.1.5 are supported.

[CPS]

  • Added the following files:
    CPS_CJ1W-ETN21_Ver1_5_mode21.xml
    CPS_CJ1W-ETN21_Ver1_5_mode11.xml
    CPS_CS1W-ETN21_Ver1_5_mode21.xml
    CPS_CS1W-ETN21_Ver1_5_mode11.xml
Improved functions
  • Solved the following problems:
    When registering SYSMAC BUS/2 in I/O table, channel allocations may have failed.

[CX-One Upgrade Utility ]

  • Solved the following problem: Sometimes it took several days until updates become actually available after announcement.

- :Version V2.* → CX-One Version 2 Auto-update (February 2009)    (Including CPS)

New functions

[CPS]

  • Added the following files
    CPS_CP1H-X40DR-A_Ver1_2.xml
    CPS_CP1H-X40DT1-D_Ver1_2.xml
    CPS_CP1H-X40DT-D_Ver1_2.xml
    CPS_CP1H-XA40DR-A_Ver1_2.xml
    CPS_CP1H-XA40DT1-D_Ver1_2.xml
    CPS_CP1H-XA40DT-D_Ver1_2.xml
    CPS_CP1H-Y20DT-D_Ver1_2.xml

- :Version V2.* → CX-One Version 2 Auto-update (December 2008)    (Including CPS)

New functions

[Auto Update System Upgraded]

  • Auto update system has been upgraded to improve the response performance and usability.

[CPS]

  • Added the following files
    CPS_CJ1W-ID212_Ver0_0.xml
    CPS_CJ1W-ID233_Ver0_0.xml
    CPS_CJ1W-OD213_Ver0_0.xml
    CPS_CJ1W-OD234_Ver0_0.xml
    CPS_CJ1W-LCB01_Ver3_6.xml
    CPS_CJ1W-LCB03_Ver3_6.xml
    CPS_CS1W-LCB01_Ver3_6.xml
    CPS_CS1W-LCB05_Ver3_6.xml

- :Version V2.* → CX-One Version 2 Auto-update (October 2008)    (Including CPS)

New functions

[CPS]

  • Added the following files
    CPS_NS8-TV10-V2.xml
    CPS_NS8-TV11-V2.xml
Improved functions

Solved the following problems

  • The Controller Link was not displayed in the unit selection list of CX-Net data link setting.

- :Version V2.* → CX-One Version 2 Auto-update (September 2008)    (Including CX-Server, CPS)

New functions
  • Supproted for CS1W-NC271/CS1W-NC471/CJ1W-NC271/CJ1W-NC471.

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)    (Including CPS)

New functions

[CPS]

  • Added the following files
    CPS_NSJ5-SQ10_Ver8_0.xml
    CPS_NSJ5-SQ11_Ver8_0.xml
    CPS_NSJ5-TQ10_Ver8_0.xml
    CPS_NSJ5-TQ11_Ver8_0.xml
    CPS_NSJ5-SQ10-G5D_Ver3_0.xml
    CPS_NSJ5-SQ11-G5D_Ver3_0.xml
    CPS_NSJ5-TQ10-G5D_Ver3_0.xml
    CPS_NSJ5-TQ11-G5D_Ver3_0.xml
    CPS_NSJ5-SQ10-M3D_Ver3_0.xml
    CPS_NSJ5-SQ11-M3D_Ver3_0.xml
    CPS_NSJ5-TQ10-M3D_Ver3_0.xml
    CPS_NSJ5-TQ11-M3D_Ver3_0.xml
    CPS_NSH5-SQ10-V2.xml
    CPS_NS5-MQ10-V2.xml
    CPS_NS5-MQ11-V2.xml
    CPS_NS5-SQ10-V2.xml
    CPS_NS5-SQ11-V2.xml
    CPS_NS5-TQ10-V2.xml
    CPS_NS5-TQ11-V2.xml
    CPS_CJ1H-CPU64H-R_Ver4_2.xml
    CPS_CJ1H-CPU65H-R_Ver4_2.xml
    CPS_CJ1H-CPU66H-R_Ver4_2.xml
    CPS_CJ1H-CPU67H-R_Ver4_2.xml
Improved functions
  • Solved the problem that the changed parameters of routing table for CLK Unit(Level#1) on C-series PLC are not transferred.
  • Solved the problem of the possibility that illegal data is written in DM area of C200HE(-Z), C200HG(-Z), C200HS or C200HX(-Z) if the value is continuously changed by using the PLC memory window in CX-Programmer.

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)    (Including CPS)

New functions

[CPS]

  • Added the following files
    CPS_CP1L-L10DR-A_Ver1_0.xml
    CPS_CP1L-L10DR-D_Ver1_0.xml
    CPS_CP1L-L10DT1-D_Ver1_0.xml
    CPS_CP1L-L10DT-A_Ver1_0.xml
    CPS_CP1L-L10DT-D_Ver1_0.xml
    CPS_CP1L-M60DR-A_Ver1_0.xml
    CPS_CP1L-M60DR-D_Ver1_0.xml
    CPS_CP1L-M60DT1-D_Ver1_0.xml
    CPS_CP1L-M60DT-A_Ver1_0.xml
    CPS_CP1L-M60DT-D_Ver1_0.xml
    CPS_CP1L-L14DT-A_Ver1_0.xml
    CPS_CP1L-L20DT-A_Ver1_0.xml
    CPS_CP1L-M30DT-A_Ver1_0.xml
    CPS_CP1L-M40DT-A_Ver1_0.xml

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)    (Including CPS)

New functions

Support for CompoNet Network

  • The CompoNet network is supported.

[CPS]

  • Added the following files
    CPS_CJ1W-PH41U_Ver1.0.xml
    CPS_CompoNet.xml
Improved functions
  • When verification of routing table was executed after transferring the table to C/CV series PLC, the comparison for the table was failed. This problem was solved.

[CPS]

  • Corrected the following files
    Cps.dtd
    CPS_CJ1W-CRM21(MODE0)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE1)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE2)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE3)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE8)_Ver1_3.xml
    CPS_CJ1W-CRM21_Ver1_1.xml
    CPS_CJ1W-CRM21_Ver1_2.xml
    CPS_CS1W-CRM21(MODE0)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE1)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE2)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE3)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE8)_Ver1_3.xml
    CPS_CS1W-CRM21_Ver1_1.xml
    CPS_CS1W-CRM21_Ver1_2.xml

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)    (Including CPS)

New functions
  • Added the following files
    CPS_CJ1H-CPU64H-R_Ver4_1.xml
    CPS_CJ1H-CPU65H-R_Ver4_1.xml
    CPS_CJ1H-CPU66H-R_Ver4_1.xml
    CPS_CJ1H-CPU67H-R_Ver4_1.xml
    CPS_CJ1W-AD04U_Ver0_0.xml
    CPS_CJ1W-LCB01_Ver3_5.xml
    CPS_CJ1W-LCB03_Ver3_5.xml
    CPS_CJ1W-NCF71_Ver2_1.xml
    CPS_CJ1W-V680C11_Ver0_0.xml
    CPS_CJ1W-V680C12_Ver0_0.xml
    CPS_CS1W-CLK13_Ver1_0.xml
    CPS_CS1W-LCB01_Ver3_5.xml
    CPS_CS1W-LCB05_Ver3_5.xml
    CPS_CS1W-NCF71_Ver2_1.xml
    CPS_CS1W-SRM21(2CH)_Ver0_0.xml
    CPS_CS1W-SRM21_Ver0_0.xml
    CPS_CS1W-V680C11_Ver0_0.xml
    CPS_CS1W-V680C12_Ver0_0.xml
    CPS_CS1W-MC421(-V1)_Ver1_1.xml
    CPS_CS1W-MC221(-V1)_Ver1_1.xml

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (October 2007)    (Including CPS)

Improved functions

Corrected the following files

  • CPS_CJ1W-PRT21_Ver0_0.xml

- :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)    (Including CPS)

New functions
  • Added the following files
    CPS_CJ1W-CLK23_Ver2_0.xml
    CPS_CJ1W-SPU01_Ver2_0.xml
    CPS_CS1D-CPU65H_Ver2_0.xml
    CPS_CS1D-CPU67H_Ver2_0.xml
    CPS_CS1W-CLK13_Ver2_0.xml
    CPS_CS1W-CLK23_Ver2_0.xml
    CPS_CS1W-CLK53_Ver2_0.xml
    CPS_CS1W-SPU01_Ver2_0.xml
    CPS_CS1W-SPU02_Ver2_0.xml
    CPS_TJ1-MC04_Ver0_0.xml (English only)
    CPS_CJ1W-ADG41_Ver1_0.xml (Japanese only)
  • Updated the following files
    CPS_CJ1W-CRM21(MODE0)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE1)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE2)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE3)_Ver1_3.xml
    CPS_CJ1W-CRM21(MODE8)_Ver1_3.xml
    CPS_CJ1W-OD232_Ver0_0.xml
    CPS_CJ1W-SPU01_Ver1_3.xml
    CPS_CS1W-CRM21(MODE0)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE1)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE2)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE3)_Ver1_3.xml
    CPS_CS1W-CRM21(MODE8)_Ver1_3.xml
    CPS_CS1W-SPU01_Ver0_0.xml
    CPS_CS1W-SPU01_Ver1_0.xml
    CPS_CS1W-SPU01_Ver1_3.xml
    CPS_CS1W-SPU02_Ver0_0.xml
    CPS_CS1W-SPU02_Ver1_0.xml
    CPS_CS1W-SPU02_Ver1_3.xml
  • Newly supports the parameter setting of SPU Unit in I/O Table.
  • Newly supports Windows Vista.
Improved functions
  • Improved the PLC memory function so that the saved data before monitoring can be automatically displayed after monitoring.
  • Solved the problem in which "Others" was displayed for device type when CPS files were saved and then opened, if PLC device type was set to "CPU-R" in CLK Datalink Table.

- :Version 2.04 → CX-One Version 2.0 Auto-update (June 2007)    (CPS含む)

New functions
  • Added the following CPS files
    CPS_CJ1W-MCH71_Ver3_1.xml
    CPS_CS1W-MCH71_Ver3_1.xml

- :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)    (Including CPS)

New functions

Support of New Types

  • CJ1-H-R and CP1L are supported.
    CJ1H-CPU**H-R
    CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, and CP1L-M40D*-*
  • CS1W-CRM21 Unit Ver.1.3 and CJ1W-CRM21 Unit Ver.1.3 are supported.
  • Added the following files
    CPS_CS1W-MCH71_Ver3_0.xml
    CPS_CS1W-PDC55_Ver1_1.xml
    CPS_CS1W-PTS55_Ver1_1.xml
  • Corrected the following files
    CPS_C200H-AD003_Ver0_0_Adjustment.xml
    CPS_C200H-CT001-V1_Ver0_0_Gate_Latch_Sampling.xml
    CPS_C200H-CT001-V1_Ver0_0_Linear_Circular.xml
    CPS_C200H-CT001-V1_Ver0_0_Preset.xml
    CPS_C200H-CT002_Ver0_0_Gate_Latch_Sampling.xml
    CPS_C200H-CT002_Ver0_0_Linear_Circular.xml
    CPS_C200H-CT002_Ver0_0_Preset.xml
    CPS_C200H-CT021_Ver0_0_Gate_CumulativeGate_Sampling.xml
    CPS_C200H-CT021_Ver0_0_Linear_Circular.xml
    CPS_C200H-CT021_Ver0_0_Preset.xml
    CPS_C200H-CT021_Ver0_0_SimpleCounter.xml
    CPS_C200H-DA003_Ver0_0_Adjustment.xml
    CPS_C200H-DA004_Ver0_0_Adjustment.xml
    CPS_C200H-MAD01_Ver0_0_Adjustment.xml
    CPS_CJ1W-AD081_Ver0_0.xml
    CPS_CJ1W-DA021_Ver0_0.xml
    CPS_CJ1W-DA041_Ver0_0.xml
    CPS_CJ1W-DA08C_Ver0_0.xml
    CPS_CJ1W-DA08V_Ver0_0.xml
    CPS_CJ1W-MAD42_Ver0_0.xml
    CPS_CJ1W-MCH71_Ver3_0.xml
    CPS_CJ1W-PDC15_Ver0_0.xml
    CPS_CJ1W-PTS15_Ver0_0.xml
    CPS_CJ1W-PTS16_Ver0_0.xml
    CPS_CJ1W-TC001_Ver0_0.xml
    CPS_CJ1W-TC002_Ver0_0.xml
    CPS_CJ1W-TC003_Ver0_0.xml
    CPS_CJ1W-TC004_Ver0_0.xml
    CPS_CJ1W-TC101_Ver0_0.xml
    CPS_CJ1W-TC102_Ver0_0.xml
    CPS_CJ1W-TC103_Ver0_0.xml
    CPS_CJ1W-TC104_Ver0_0.xml
    CPS_CJ1W-TS561(3ch)_Ver0_0.xml (English version only)
    CPS_CJ1W-TS561(4ch)_Ver0_0.xml (English version only)
    CPS_CJ1W-TS561(6ch)_Ver0_0.xml (English version only)
    CPS_CJ1W-TS562(3ch)_Ver0_0.xml (English version only)
    CPS_CJ1W-TS562(4ch)_Ver0_0.xml (English version only)
    CPS_CJ1W-TS562(6ch)_Ver0_0.xml (English version only)
    CPS_CS1W-AD041_Ver0_0.xml
    CPS_CS1W-AD081_Ver0_0.xml
    CPS_CS1W-AD161_Ver0_0.xml
    CPS_CS1W-DA041_Ver0_0.xml
    CPS_CS1W-DA08C_Ver0_0.xml
    CPS_CS1W-DA08V_Ver0_0.xml
    CPS_CS1W-MAD44_Ver0_0.xml
    CPS_CS1W-PDC55_Ver0_0.xml
    CPS_CS1W-V600C11_Ver0_0.xml
    CPS_CS1W-V600C12_Ver0_0.xml

- :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)    (CPS Library Only)

New functions
  • Added the following files
    CPS_EJ1G-HFU_Ver0_0.xml
    CPS_EJ1G-TC2_Ver0_0.xml
    CPS_EJ1G-TC4_Ver0_0.xml
    CPS_CS1W-CRM21_Ver1_1.xml
    CPS_CS1W-CRM21_Ver1_2.xml
    CPS_CJ1W-CRM21_Ver1_1.xml
    CPS_CJ1W-CRM21_Ver1_2.xml

- :Version 2.03 → CX-One Version 2.0 Auto-update (December 2006)    (CPS Library Only)

New functions
  • Corrected the errors in writing in the following files:
    CS1W-V600C11
    CS1W-V600C12
  • Added the following files
    CPS_CJ_Dummy_016.xml
    CPS_CJ_Dummy_032.xml
    CPS_CJ_Dummy_048.xml
    CPS_CJ_Dummy_064.xml
    CPS_CJ_Dummy_096.xml
    CPS_CJ_Dummy_128.xml

- :Version 2.02 → CX-One Version 2.03 (November 2006)    (CPS Library Only)

New functions
  • Support of New PLC Types
  • Support of CS1D Unit Ver. 1.3.
    New Type (Ver. 1.3) --- Type CS1D-CPU**H are supported.
  • Support the expansion of error log up to 96 records in CS1W-DRM21-V1 and CJ1W-DRM21.

Change history of CX-Server

Ver.3.22 : Version V2.* → CX-One Version 2 Auto-update (June 2009)

Improved functions
  • The Controller Link was not displayed in the unit selection list of CX-Net data link setting.

V3.21 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

Improved functions
  • Solved the problem that CX-Server shut down illegally when the PLC memory window in CX-Programmer was opened during the monitoring.

V3.2 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

Improved functions
  • CP1L-L10 and CP1L-M60 are supported.

CX-Server CompoNet Driver :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)

New functions

Support for CompoNet Network

  • CX-Server device driver for CompoNet

Ver.3.12 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (October 2007)

Improved functions
  • Solved the problem in which driver management tool could not be selected from Start menu on Windows Vista.

Ver.3.11 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

Improved functions
  • Solved the problem in which the application might be unexpectedly terminated when changed to offline.
  • Solved the problem in which CX-Server hanged if operated with utility attached to nVidia graphic card.

Ver.3.04 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

Support of New Types

  • CJ1-H-R and CP1L are supported.
    CJ1H-CPU**H-R
    CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, and CP1L-M40D*-*

Ver.3.03 :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)

Improved functions
  • Solved the problem in which modem connection to the CV-series unit was impossible via SYSWAY.

Ver.3.02 :Version 2.02 → CX-One Version 2.03 (November 2006)

New functions

Support of New PLC Types

  • Support of CS1D Unit Ver. 1.3 and FQM1 Unit Ver. 3.2.
    New Type (Ver. 1.3) --- Type CS1D-CPU**H
    New Type (Ver. 3.2) --- Type FQM1-CM***, Type FQM1-MMA**, and Type FQM1-MMP**
Improved functions
  • Improved the connectivity for reconnection of FINS/TCP.
  • Solved the problem in which the UM/EM sizes are not correctly recognized when auto online function to CJ1H-CPU67H is executed in CX-Programmer.

CX-Server&Drivers Ver.3.0 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • CS/CJ-series CPU Units with Unit Version 4.0 are supported.
  • CP1HY CPU Units are supported.

CX-Programmer Change history of

Ver.7.31 :Version V2.* → CX-One Version 2 Auto-update (April 2009)

Improved functions
  • Solved the following problems:
    When you repeated print previews of SFC chart, the memory may have run out.
    FB instance may have changed into improper data in such a condition that a symbol named 'FBCALL' is registered in a symbol table.

Ver.7.3.0.10 :Version V2.* → CX-One Version 2 Auto-update (February 2009)

Improved functions
  • Solved the problem with auto online connection between CV-Series PLC.

Ver.7.30 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

Improved functions
  • Solved the problem that the result of compilation become internal error when there are some FB.
  • Solved the problem that PLC might operate illegally when there was a transition condition of the SFC program and the SFCPR instruction and the SFCON instruction in another program.
  • Solved the problem that CX-Programmer shut down illegally when there are some action ladder of SFC program in compiling.

Ver.7.30 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

New functions

Support of New Types

  • CP1L-L10 and CP1L-M60 are supported.
    CP1L-L10D*-*
    CP1L-M60D*-*

Ver.7.23 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)

Improved functions
  • Solved the problem with displaying the ST task size of the task property.
  • Solved the problem with comparing program which included Task read protect.

Ver.7.22 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

Improved functions
  • File opening/closing time became quick, when there are some FB.

Ver.7.21 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

Improved functions
  • The improvement which matches the operativity of old version
    If program was downloaded to PLC by Ver. 6.11 or earlier CX-Programmer, when verification was executed by Ver. 7.20, the comparison for function blocks was failed. This problem was solved.
  • In the bit address change on ladder view, error message was not displayed even if a symbol with the same name existed. This problem was solved.
  • Solved the problem in which symbols for the operands using more than one word were not correctly displayed in the cross-reference report.
  • Solved the problem in which Layout Printing did not correctly function on Windows Vista, which occurred in CX-Programmer upgraded from Ver. 2.0x to Ver. 2.10/2.11.

Ver.7.20 :Version 2.0*/2.10/2.11 → CX-One Version 2 Auto-update(September 2007)

Improved functions

The improvement which matches the operativity of old version

  • Solved the problem in which same-address words could not be detected when any bit other than Bit 0 was specified in Cross-Reference.
  • Solved the problem in which data type could not be changed together with symbol name when Edit button is selected on the Edit Instruction dialog.
  • Solved the problem in which rung error occurred when a file including a specific symbol name (that includes GD/GW) was loaded.

Ver.7.20 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions

Enhancement of IEC61131-3 compliant languages

  • Newly supports ST language as a language of program (allocated to tasks).
  • Newly supports SFC language as a language of program (allocated to tasks).
  • Newly supports the symbols for specifying array on ladder/ST/SFC programs.
  • It has become possible to verify function block definitions.
  • It has become possible to verify ST programs and the action programs/transition programs/subcharts in SFC.

Enhancement of Symbol Table.

  • Enhanced the coordination with CX-Designer for symbol table data.
  • Newly supports String type as a symbol data type in ladder programs and ST programs.

Enhancement of auto online connecting function.

  • Added the automatic search function of PC serial ports.
Improved functions

Enhancement of support functions for SYSMAC C500/C120/C**P

  • It has become possible to convert the DM/HR Area data to PLC Memory when uploading the programs in SYSMAC C500/C120/C**P and converted to the programs for CS/CJ/CP-series PLC or CVM1/CV-series PLC.
  • It has become possible to convert the backed up programs and I/O memory (DM/HR) files (.c5b) to CX-P project for CS/CJ/CP-series PLC or CVM1/CV-series PLC.
  • It has become possible to save the programs uploaded from SYSMAC C500/C120/C**P in the mnemonic text format. By pasting this data as a text on the statement list of CX-Programmer and displaying/printing in the ladder format, it is possible to check the programs before conversion for CS/CJ/CP-series PLC or CVM1/CV-serives PLC on CX-Programmer.

Others

  • For SYSMAC CS1D Duplex CPU System (CS1D-H), it has become possible to display the Active/Standby status of CPU Unit on the project tree.

CX-Programmer Common :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Added the CX-Programmer library.

Ver.7.11 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

New functions

Support of New Types

  • CJ1-H-R and CP1L are supported.
    CJ1H-CPU**H-R
    CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, and CP1L-M40D*-*

Ver.7.03 :Version 2.02 → CX-One Version 2.03 (November 2006)

New functions

Support of New PLC Types

  • Support of CS1D Unit Ver. 1.3 and FQM1 Unit Ver. 3.2.
    New Type (Ver. 1.3)--- Type CS1D-CPU**H
    New Type (Ver. 3.2) ---Type FQM1-CM***, Type FQM1-MMA**, and Type FQM1-MMP**
Improved functions
  • By modifying CX-Server, Solved the problem in which the UM/EM sizes of CJ1H-CPU66H are displayed on the Project window in the case of auto online to CJ1H-CPU67H.

Ver.7.02 :Version 2.01 → CX-One Version 2.02 (October 2006)

Improved functions
  • Solved the problem in which the FB instances with the same name are doubly registered in the symbol table when FB program is uploaded.

Ver.7.01 :Version 2.01 → CX-One Version 2.0 Auto-update (September 2006)

Improved functions
  • Solved the problem in which a certain lot of C200H-IP007 Units could not communicate properly with the C500, C120, and C**P Backup Function

Ver.7.00 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New PLC Models

  • CS/CJ-series CPU Units with unit version 4.0 are supported.
    New models (unit version 4.0): Compatible with the CS1G-CPU**H,CS1H-CPU**H, CJ1G-CPU**H, CJ1H-CPU**H, and CJ1M-CPU**.
  • The SYSMAC One NSJ-M3D Series is supported.
    New models: Compatible with the NSJ5-TQ0*-M3D,NSJ5-SQ0*-M3D, and NSJ8-TV0*-M3D.

Improvements to Function Block Functions

  • Supports conversion to ladder program FBs.
    Function block definitions can be created easily from ladder programs.
  • Supports input-output variables.
    Input-output parameters can be specified in function blocks.
  • Supports online function block editing.
    Function block definitions can be changed in an operating PLC.
  • Improvements to ST function blocks
  • The STRING data type can be used. Text processing functions can be used to easily manipulate text strings and process display messages.

Supports Conversion of Earlier PLC’s Programs

  • A C500, C120, or C**P PLC program can be uploaded and converted to a CS/CJ/CP -series PLC program or CVM1/CV-series PLC program.
  • The program and I/O memory data stored in a C500, C120, or C**P PLC can be backed up, restored, and verified.

Improvements to the Data Trace and Time Chart Monitor Functions

  • Two-word data can be specified and traced.
Improved functions

Editing I/O Comments

  • Solved the problem that caused hidden comments to be lost if comments were changed in the ladder view when registering multiple I/O comments.

Checking the Program

  • Solved the problem in which a program error was detected if FOR-NEXT instructions were used between MULTI-INTERLOCK instructions.

Cross Reference Reports

  • Corrected the problem which took a long time to copy more than a few thousand data items at a time.

Monitoring

  • Solved the problem that prevented connecting lines from connecting properly to a text string comparison instruction.
  • Solved the problem that prevented the monitoring of LREAL variable data when connected to an FQM1 CPU Unit with unit version 3.0.

Transferring Programs

  • Solved the problem that prevented the proper transfer of a program with a Customizable Counter Unit if the program contained a MOVL instruction.

Verifying Programs

  • Solved the problem that caused verification errors with a nested PLC program when the nested program was read from the PLC and stored.

Data Trace

  • Solved the problem which prevented the previous trace trigger setting from being read from the PLC.

Change history of SwitchBoxUtility

Ver.1.6.3.1 :Version V2.* → CX-One Version 2 Auto-update (August 2007)

New functions

[Support of New Types]

CJ1-H-R and CP1L are supported.

  • CJ1H-CPU**H-R
  • CP1L-L10D*-* , CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, CP1L-M40D*-*, and CP1L-M60D*-*

Ver.1.62 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New PLC Models

The SYSMAC One NSJ-M3D Series is supported.

  • New models: Compatible with the NSJ5-TQ0*-M3D,NSJ5-SQ0*-M3D, and NSJ8-TV0*-M3D.

CP1H CPU Units are supported.

  • New models: Compatible with the CP1H-XA****-*,CP1H-X****-*, and CP1H-Y****-*.

Change history of CX-Integrator

Ver.2.24 :Version V2.* → CX-One Version 2 Auto-update (April 2009)

New functions
  • Support the DeviceNet sensor module: E3X-DRT21-S V3.

Ver.2.23 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

New functions

Support of New Types

  • THERMAC EJ1N(Standard Control Models) Ver.1.2 are supported.
    Supports the new version models: EJ1N-TC2*-QNHB, EJ1N-TC4*-QQ, EJ1N-TC2*-CNB

Ver.2.22 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

New functions
  • EDS file for DeviceNet ID Slave, V680-HAM42-DRT is added.
  • Supports the new models:GRT1-TS2T、GRT1-IA4-1、GRT1-IA4-2.
  • SmartSlice DeviceNet Communication unit (GRT1-DRT) Ver.2.0 are supported.
    (Newly supports Software Setting of I/O Allocations function.)

Ver.2.20 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)

New functions

Support for CompoNet Network

  • The CompoNet network is supported.
Improved functions
  • Solved the problem in which the I/O size of E3X-DRT21-S are not correctly calculated.

Ver.2.12 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions

Support of New Types

  • THERMAC EJ1N(Standard Control Models) DeviceNet Communications Unit are supported.
    New Models: Compatible with the EJ1N-HFUB-DRT.
  • SmartSlice GRT1-series Temperature Input Unit (Platinum resistance thermometer;Pt1000)(GRT1-TS2PK) are supported.

Ver.2.11 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (October 2007)

New functions
  • Remote I/O Terminals with Screw-less Clamps (transistor type) (Model: DRT2-*D16SL(H)-1)) was added.
Improved functions
  • Solved the problem in which data link was cancelled if a node for which SYSMAC LINK data link table has an error was monitored on the data link status view.

Ver.2.10 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Addressed the increase in the datalink capacity in Controller Link (4,000 words/node).
  • Enhanced the function for setting Routing Table via network.
  • Addressed the expansion of relay network table in Routing Table (64 nodes max.).
Improved functions
  • Improved the transfer function for DeviceNet network.
  • Improved the transfer function for CompoWay/F network.

Ver.2.06 (2007/4/30)

New functions

Support of New Types

  • CJ1-H-R and CP1L are supported.
    CJ1H-CPU**H-R
    CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, and CP1L-M40D*-* are newly supported.

Ver.2.04 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

New functions

Support of New Types

  • New SmartSlice I/O units are supported.
    GRT1-ID8(-1), GRT1-OD8(-1)

Ver.2.03 :Version 2.02 → CX-One Version 2.03 (November 2006)

New functions
  • Support the expansion of error log up to 96 records in CS1W-DRM21-V1 and CJ1W-DRM21.
Improved functions
  • Solved the problem in which the program abnormally terminated while displaying the English-version help file.

Ver.2.00 (No change to version number) :Version 2.01 → CX-One Version 2.0 Auto-update (September 2006)

New functions

Compatibility with New PLC Models

  • SmartSlice GRT1-series Counter Units are supported.
    New models: Compatible with the GRT1-CT1(-1).

Ver.2.00 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New PLC Models

  • CS/CJ-series CPU Units with unit version 4.0 are supported.
    New models (unit version 4.0): Compatible with the CS1G-CPU**H,CS1H-CPU**H, CJ1G-CPU**H,CJ1H-CPU**H, and CJ1M-CPU**.
  • The SYSMAC One NSJ-M3D Series is supported.
    New models: Compatible with the NSJ5-TQ0*-M3D, NSJ5-SQ0*-M3D, and NSJ8-TV0*-M3D.

Compatibility with New Models

  • RoHS-compatible DRT2 (DeviceNet Slave) Units are supported.
    Compatible with the DRT2-HD16CL, DRT2-HD16CL-1, DRT2-ID08CL,
    DRT2-ID08CL-1, DRT2-OD08CL, DRT2-OD08CL-1, DRT2-ID08, DRT2-ID08-1,
    DRT2-OD08, DRT2-OD08-1, DRT2-MD16, DRT2-MD16-1, DRT2-ID16ML,
    DRT2-ID16ML-1, DRT2-OD16ML, DRT2-OD16ML-1, DRT2-MD16CL,
    DRT2-MD16CL-1, DRT2-WD16CL, DRT2-WD16CL-1, DRT2-ID04CL,
    DRT2-ID04CL-1, DRT2-OD04CL, and DRT2-OD04CL-1.

Network View

  • The relationship between network connections can be displayed in an easy-to-understand format with the System Overview display and PLC Gateway display.
  • The display can be switched between networks with just one click.

Uploading from Network

  • When uploading from the network, any network name can be input.
  • When uploading from the network, it is possible to upload only the different information from a node in the network.

Registering Components

  • Registration operations have been improved by adding a wizard that can be used to register components and networks.

Other Upgrades

  • Network and node information can be checked together in the Property Window.
  • When downloading a CLK data link, the data link mode (manual/auto) setting can be checked.
  • Multiple CPS files can be installed simultaneously.
Improved functions
  • Solved the problem with the echoback test, which counted a test as successful even if the response time exceeded the monitoring time.
  • Solved the problem which prevented the upload of an Ethernet (FINS/TCP) network’s configuration.
  • Solved the problem which caused the CQM1H-CPU61 model number to be displayed incorrectly as a data link component.
  • Solved the problem at data link startup which displayed a warning message indicating that there is no routing table.
  • Made it possible to select CompoWay/F or NT Link as the network type when starting the CX-Integrator from the CX-Programmer’s I/O table.
  • Improved the message displayed when data is write-protected and a routing table is downloaded.

Change history of CX-Protocol

Ver.1.71 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

New functions

Support of New Types

  • CJ1-H-R is supported.

Ver.1.7 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New PLC Models

  • The SYSMAC One NSJ-M3D Series is supported
    New models: Compatible with the NSJ5-TQ0*-M3D, NSJ5-SQ0*-M3D,and NSJ8-TV0*-M3D.
  • CP1H CPU Units are supported.
    New models: Compatible with the CP1H-XA****-*, CP1H-X****-*, and CP1H-Y****-*.
  • Supports Protocol Comparison
    It is possible to compare protocols in each PMSU mounted in the connected PLC.

Change history of CX-Simulator

Ver.1.80 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

Improved functions
  • Solved the problem that CX-Programmer does not connect CX-Simulator by compatibility with the residing application.

Ver.1.80 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

Support of New Types

  • CP1L-L10 and CP1L-M60 are supported.
    CP1L-L10D*-*
    CP1L-M60D*-*

Ver.1.80 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Newly supports CX-Programmer Ver. 7.20.

Ver.1.80 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

New functions
  • Support of New Types
    CJ1-H-R and CP1L are supported.
    CJ1H-CPU**H-R
    CP1L-L14D*-*, CP1L-L20D*-*, CP1L-M30D*-*, and CP1L-M40D*-*

Ver.1.7 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New PLC Models

  • CS/CJ-series CPU Units with unit version 4.0 are supported.
    New models (unit version 4.0): Compatible with the CS1G-CPU**H, CS1H-CPU**H, CJ1G-CPU**H, CJ1H-CPU**H,and CJ1M-CPU**.
  • The SYSMAC One NSJ-M3D Series is supported.
    New models: Compatible with the NSJ5-TQ0*-M3D, NSJ5-SQ0*-M3D, and NSJ8-TV0*-M3D.
  • CP1H CPU Units are supported.
    New models: Compatible with the CP1H-XA****-*, CP1H-X****-*, and CP1H-Y****-*.

Supports the PLC-PT Integrated Simulation Function

  • By selecting PLC-PT Integrated Simulation from the CX-Designer’s menu, the user program can be executed in a virtual PLC in order to debug associated PT screens.

Change history of CX-Position

Ver.2.40 :Version 2.04 → CX-One Version 2.0 Auto-update (June 2007)

New functions
  • The connection of Position Control Unit is supported in FQM1 series.
  • Windows Vista is supported.

Ver.2.3 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • A greater variety of operations can be performed from previous version. In addition to jogging, direct operation and origin searches can be executed.

Change history of CX-Motion-NCF

Ver.1.71 : Version V2.* → CX-One Version 2 Auto-update (October 2009)

New functions
  • Supports the G5-series Servomotor/Servo Drives with built-in MECHATROLINK-II communications.

Ver.1.7 :Version V2.* → CX-One Version 2 Auto-update (September 2008)

New functions
  • Supproted for CS1W-NC271/CS1W-NC471/CJ1W-NC271/CJ1W-NC471.

Ver.1.51 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (July 2008 additional)

New functions

[Support of New Types]

  • Added support for G-series servo dirves with MECHATROLINK-Ⅱ communication I/F.

Ver.1.50 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Newly supports Windows Vista.

Ver.1.4 :Version 2.02 → CX-One Version 2.03 (November 2006)

New functions

Support of New Types

  • Supports SMARTSTEP Junior Servo Driver.
  • Supports CS1W/CJ1W-NCF71 Ver. 2.0.

Change history of CX-Motion-MCH

V2.10 :Version 2.04 → CX-One Version 2.0 Auto-update (June 2007)

New functions

Support of New Types

  • MCH Units (Ver. 3.1) and SMARTSETP Junior are supported.
    CS1W/CJ1W-MCH71 (Ver. 3.1) are newly supported.
    R7D-ZN***-ML2 is newly supported.
  • Windows Vista is supported.

V2.04 :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)

Improved functions
  • Solved the problem in which the data imported from Miel could not be downloaded to MCH due to compile error.

V2.03 :Version 2.03 → CX-One Version 2.0 Auto-update (December 2006)

Improved functions
  • Solved the problem in which the data setting warning appeared in the servo driver when the servo parameters are downloaded or saved.

V2.02 :Version 2.02 → CX-One Version 2.03 (November 2006)

Improved functions
These two problems are solved.
  • Solved the problem in which Servo data were always sent to MCH in the parameter transfer even if “Without Servo parameter” is selected.
  • Solved the problem in which some zone watching area addresses could not be set fully.

V2.0 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Data traces can be performed in the Motion Control Unit. Trace results are displayed in a graph.
  • Operations such as jogging and origin search can be executed from the Support Software.
  • The motion program can be executed and the program can be debugged from the Support Software.

Supports Unit Version Upgrade Features

  • Supports the parameters added as part of the unit version upgrade.

Change history of CX-Motion

Ver.2.35 : Version V2.* → CX-One Version 2 Auto-update (December 2009)

Improved functions
  • Solved the problem that the date in error log dialog is not displayed correctly in some regional settings.

V2.33 :Version V2.* → CX-One Version 2 Auto-update (August 2008)

Improved functions
  • Solved the problem of special printing settings on certain printer models.

V2.32 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

Improved functions
  • Improvement of All data transfer.

V2.31 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions
  • Added support to CS1W-MC421-V1/MC221-V1 Ver.1.1 and higher

V2.30 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Newly supports Windows Vista.

V2.27 :Version 2.04 → CX-One Version 2.0 Auto-update (April 2007)

Improved functions
  • Improved the G code compiler so that the data can be transferred to MC unit even when the block numbers are arranged in random order.

V2.26 :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)

Improved functions
  • Improved the G code compiler so that the data can be downloaded to MC unit even when the line numbers are discontiguous.

V2.25 :Version 2.01 → CX-One Version 2.0 Auto-update (September 2006)

Improved functions
  • Solved the problem which failed to import the MCSS file type data(.mcq, .mca, .mcp) .
  • Solved the problem on the project tree window which could not move the icon of each data.
  • Solved the problem which prevented the data selection uploading.

V2.24 (2006/8/31)

New functions
  • When downloading data to a Motion Control Unit, the user can specify whether to save or overwrite the Unit’s ABS encoder values.

Change history of CX-Drive

Ver.1.91 : Version V2.* → CX-One Version 2 Auto-update (October 2009)

New functions
  • Supports the G5-series Servomotor/Servo Drives with built-in MECHATROLINK-II communications.

Ver.1.90 : Version V2.* → CX-One Version 2 Auto-update (August 2009)

New functions
  • Supporting inverter MX2.
Improved functions
  • Solved the problem that a part of parameters was unable to transfer to the JX/RX-series Inverters.

Ver.1.80 : Version V2.* → CX-One Version 2 Auto-update (June 2009)

New functions
  • Support G5 servo drives.

Ver.1.70 :Version V2.* → CX-One Version 2 Auto-update (April 2009)

New functions
  • Supporting 3G3RX Inverter model size addition.

Ver.1.70 :Version V2.* → CX-One Version 2 Auto-update (October 2008)

New functions
  • New Inverter series support. 3G3JX/3G3MX/3G3RX

Ver.1.62 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (July 2008 additional)

New functions

[Support of New Types]

  • Added support for new Servos in America and Asia, and CJ2 CPU, EtherNet/IP connections.
Improved functions
  • Improved Servo Drive Data Trace Function.

Ver.1.61 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

New functions

Support of New Types

  • Added support for new Servos in America and Asia.
  • Added New functionality on Servo Drive Data Trace.

Ver.1.40 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Newly supports Windows Vista.

Ver.1.31 :Version 2.02 → CX-One Version 2.03 (November 2006)

New functions
  • Support RV/RV-V1 version up.

Ver.1.3 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Supports Inverter models with the version upgrade (RV-V1).

Change history of CX-Process Tool

Ver.5.23 :Version V2.* → CX-One Version 2 Auto-update (April 2009)

New functions
  • Support new loop control board and loop cpu unit (Unit ver.3.6)
  • Support EtherNet/IP protocol
Improved functions
  • Solved problem that some parameters were displayed in illegal engineering value.

Ver.5.22 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

New functions
  • Improvements of GTC Loop controllers are supported.
Improved functions
  • Solved the problem that HMI I/F stops after a Function Block is transferred to Loop controller.

Ver.5.21 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)

Improved functions
  • Corrected the problem which caused an exception when the mouse cursor was moved around on annotations, while running the operation check of Block Diagrams.
  • Corrected the problem which caused an exception when it moves to the node of specification from the message which is indicated in the Outputwindow.

Ver.5.20 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions

Supports the new version models

  • Loop Contorol Board:CS1W-LCB01,CS1W-LCB05
  • Loop-contorol CPU Unit:CJ1G-CPU **P

Engineering unit display

  • An ITEM can be displayed and set in engineering units,based on scaling information(CSV tag information) for individual function blocks.
Improved functions

Enhanced Project Editing Function

  • Data, such as verification result,is displayed in special windows.Supports Jumping to the relevant location from displayed results.
  • Improved sequence for creating new function block data.
  • Improved method for adding function blocks.

Ver.5.12 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Installation of Introduction Manual has become possible.

Ver.5.12 :Version 2.03 → CX-One Version 2.0 Auto-update (December 2006)

Improved functions
  • Solved the problem that the version of Process CPU (Model CS1D-CPU6*P) was illegally displayed when version check function was executed.

Ver.5.11:Version 2.02 → CX-One Version 2.03 (November 2006)

Improved functions
  • Corrected the errors in dialog text strings of English version.
  • Solved the problem in which the program abnormally terminated while displaying English-version tuning screen.
  • Solved the problem in which the grid disappeared in the GTC mode conversion matrix input dialog.

Ver.5.1 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Supports Controllers for gradient temperature control (CJ1G-CPU45P-GTC and CS1W-LCB05-GTC).

Change history of FP Auto-Builder for NS

Ver.3.11 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

Improved functions
  • Solved the problem that the project built in the condition of settings that the first data log number is not set to default value contains a illegal data.

Ver.3.00 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions
  • Projects can be output in NS System version 6.6.
  • Projects can be output in NS Runtime version 6.6.
  • Face Plates can be built for the function block 'Segment Program 3(Block Model 158)'

Change history of FP Auto-Builder for NS (NSFP)

Ver.3.1 :Version V2.* → CX-One Version 2 Auto-update (August 2008)

New functions
  • Projects can be output in NS System version 6.6.
  • Projects can be output in NS Runtime version 6.6.
  • Face Plates can be built for the function block 'Segment Program 3(Block Model 158)'

Ver.3.10 :V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions
  • Added to the compatible function blocks.
  • Added a function that automatically inputs comments to unit and scale settings.

Ver.3.0 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Added to the compatible function blocks.
  • Added a function that automatically inputs comments to unit and scale settings.

Change history of CX-Designer

Ver.2.112 :Version V2.* → CX-One Version 2 Auto-update (August 2008)

Improved functions
  • Solved the problem that the TIM area may not be properly displayed by numeral input object.

V2.111 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

Improved functions
  • Solved the problem in which the result of Address Cross Reference's operation was not correctly shown.

V2.11 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (February 2008)

New functions
  • Newly supports Modbus RTU.

V2.104 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

Improved functions
  • Solved the problem in which the display format could not be reflected in the maximum and minimum values in TENKEY dialog in Test Mode.

Ver.2.103 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (November 2007)

New functions
  • Newly supports Mitsubishi Q and QnA series PLCs.
  • Newly supports Rockwell(Allen-Bradley) PLC-5,SLC500,MicroLogix,CompactLogix and ControlLogix series PLCs.

Ver.2.10 :Version 2.0*/2.10/2.11 → CX-One Version 2 Auto-update(September 2007)

Improved functions
  • Solved the problem that occurred while operating in the Label Tab Page of the Table Object Properties.

Ver.2.10 :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Newly supports the Machine Navigator Function.
  • Newly supports the Multifunction Objects.
  • Newly supports the higher quality fonts.
  • Newly supports the import of DXF file.
  • Newly supports the startup of PLC Error Simulator.
Improved functions
  • Enhanced the coordination in the integrated simulation and added the zoom function.
  • In the symbol sharing with CX-Programmer, additionally supported the string type and the array. It has also become possible to paste even when the address is duplicated.
  • Changed the default setting for the shape of buttons and lamps (excluding word lamp) so as to specify the shape ("Select Shape").
  • Additionally supported the multi-vendor devices.
  • Enhanced the compatibility with NT-series PTs.
  • Enhanced the copy/paste function in Edit Properties.

Ver.2.03 :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)

New functions

Support of New Types

  • NS-Runtime is supported.
    New model: NS-NSRCL*
  • Traditional Chinese is supported.

Ver.2.02 :Version 2.01 → CX-One Version 2.02 (October 2006)

Improved functions
  • Solved the problem that when some Smart Active Parts (for NC/MCH units) were pasted and unit numbers were set to other than 0, these Smart Active Parts might not operate properly.

Ver.2.01 :Version 2.01 → CX-One Version 2.0 Auto-update (September 2006)

Improved functions
  • Solved the problem with the CX-Designer, in which allocated addresses (such as object addresses) were unintentionally changed when screens were saved under certain conditions before exiting the CX-Designer.

Ver.2.0 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Test Functions

  • Supports integrated simulation (in association with the CX-Simulator).

Multi-vendor PLC Support

  • Supports connections with EJ1-series Temperature Controllers, some Mitsubishi PLCs, and some Siemens PLCs.

Improvements to Variable-related Functions

  • Supports variable programming.
  • Names and I/O comments within the symbol table can be reflected in labels and alarm messages.

Security Measures

  • Supports read/write protection of screen data.
  • Different password protection levels can be set for screen objects.

Supports Multiple Languages

  • Supports simplified Chinese, German, Italian, French, and Spanish (CX-Designer menu items and dialogue boxes).

Change history of CX-Thermo

Ver.4.00 :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (December 2007)

New functions

Support of New Types

  • THERMAC NEO basic type and advanced type (release on Jan of 2008) are supporte
    Supports the new E5CN-H, E5EN-H and E5AN-H
    Also, supports the new version models: E5CN, E5EN and E5AN

Enhanced Parameter Editing Function

  • Parameters in table format can be edited.
  • Each information window can be freely laid out.

Enhanced Compatibility

  • Some models can be changed with other models.
Improved functions
  • Part number can be entered directly in a device select dialog.
  • When TrendViewer is started, PV/SP are automatically selected as parameters to monitor.
  • Often used operations are displayed on the toolbar.

Ver.3.21 :Version 2.04 → CX-One Version 2.0 Auto-update (February 2007)

New functions

Support of New Types

  • THERMAC EJ1G (Gradient Temperature Control Models) are suppoted.
    Compatible with new models: EJ1G-TC2*-QNH, EJ1G-TC4*-QQ, EJ1G-HFU*-NFLK, EJ1G-HFU*-NFL2.

Ver.3.20 :Version 2.03 → CX-One Version 2.0 Auto-update (December 2006)

New functions

Support of New Types

  • THERMAC EJ1N(Standard Control Models) Ver.1.1 are supported.
    Supports the new: EJ1N-TC2*-CNB
    Supports the new version models: EJ1N-TC2*-QNHB, EJ1N-TC4*-QQ,EJ1N-HFU*-NFLK, EJ1N-HFU*-NFL2

Display

  • Parameter tree display can be changed by selecting Expanding or Collapsing.

Configuration

  • EJ1N Programless Upload/Download settings can be configured in table format.

Trend Viewer

  • Parameters such as SP can be changed.

Ver.3.12 :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions

Compatibility with New Models

  • The THERMAC R Digital Controllers (Programmable) are supported.
    Compatible with the new E5AR-T and E5ER-T Controllers.

Trend Viewer

  • Operation commands other than RUN/STOP and Autotuning execute/cancel can be sent in the Trend Viewer.
  • It is possible to monitor the program output status of E5AR-T and E5ER-T Controllers.

Display

  • The icons and menus have been unified to the same style as the other Support Software applications in the CX-One FA Integrated Tool Package.

Change history of CompoNet DTM

- :Version V2.* → CX-One Version 2 Auto-update (August 2009)

Improved functions
  • Solved the problem that you can not install certain EDS files.

- :Version V2.* → CX-One Version 2 Auto-update (April 2009)

New functions

[Support of New Types]

  • CompoNet Slaves "CRT1" series are supported.
    CompoNet Analog I/O Slave with display function
  • CompoNet I/Os of C500 series are supported.

- :Version V2.* → CX-One Version 2 Auto-update (December 2008)

New functions

[Support of New Types]

  • CompoNet Slaves "CRT1" series is supported.
    CompoNet Analog I/O Slave Units with Connectors

- :Version V2.* → CX-One Version 2 Auto-update (October 2008)

New functions

[Support of New Types]

  • CompoNet Slaves "CRT1" series is supported.
    temperature input terminal (Thermocouple input、Platinum resistance thermometer input)
Improved functions
  • Solved the following problem
    Over 65535 value can not be used in EDS File Parameter Dialog.
  • Support the None Parameter EDS File.

- :Version V2.* → CX-One Version 2 Auto-update (September 2008)

Improved functions
  • Solved the problem that the slave (vendor code exceeds 255) cannot be used.

- :Version V2.* → CX-One Version 2 Auto-update (August 2008)

Improved functions
  • Add the error message. The message is displayed when the areas are overlapped in Software Setting Table.

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (June 2008)

New functions

Support of New Types

  • CompoNet Slaves "SmartSlice GRT1" series is supported.
    GRT1-CRT
    GRT1-ID4(-1)
    GRT1-OD4(-1)
    GRT1-ROS2
    GRT1-AD2
    GRT1-DA2C
    GRT1-DA2V
    GRT1-TS2P
    GRT1-CT1(-1)
Improved functions
  • Added the area duplication check function of Software Setting Table in Master Parameter Dialog.

- :Version V2.0*/V2.1* → CX-One Version 2 Auto-update (April 2008)

New functions

Support of New Types

  • CompoNet Slaves "CRT1" series is supported.
    2-tier terminal series (8IN/OUT、16MIX)
    3tier terminal series (8IN/OUT、Disconnected sensor/Short-circuit detection)
    Relay output series (8out)
    SSR output series (8out)
    e-CON series (32IN/OUT/MIX、Disconnected sensor/Short-circuit detection)
    Clump series (8IN/OUT、16MIX)

SmartSlice I/O Coupler DTM

- :Version V2.* → CX-One Version 2 Auto-update (June 2009)

Improved functions
  • Solved the problem that project files containing previous versions of Slice IO Coupler DTM cannot display the DTM views in CX-ConfiguratorFDT.

Change history of SAP Library

- :Version 2.0*/Version 2.10 → CX-One Version 2.11 Auto-update (August 2007)

New functions
  • Troubleshooters for Temperature Control Unit, Motion Control Unit and ID Sensor Unit are supported.

- :Version 2.01 → CX-One Version 2.02 (October 2006)

New functions
  • Added the SAP Library for CompoNet.

- :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Added SAP for the EJ1, G3ZA, troubleshooter (DeviceNet and NC Unit), and CP1H.

Change history of Function Blocks

- :Version 1.12 → CX-One Version 2.0 Upgrade (August 2006)

New functions
  • Added convenient FB#1 and function blocks for the EJ1 and CP1H.
  • Added convenient FB#2 function block.

Revision History for CX-One Version 2.03 → CX-One Version 2.04 ( February 2007 )

* Information
The version notation was changed along with the release of CD/DVD that contained the content of the change until CX-One Version 2.0 Auto-update(December 2006).
(The customers who have already updated to CX-One Version 2.0 Auto-update(December 2006) need not arrange this update.)