Troubleshooting for Unit Startup
Here are some common troubleshooting examples related to unit startup.
PWR indicator is not lit.
Use the rated power supply voltage for the Power Supply Units.
Make sure that the power cable is not broken and is connected correctly.
Make sure that the Power Supply Unit and Data Flow Controller are connected correctly.
If the PWR indicator on the Power Supply Unit does not light up even after taking the above actions, replace the Power Supply Unit.
If the PWR indicator on the Data Flow Controller still does not light up, the Data Flow Controller may be faulty. Replace it.
RUN indicator is not lit (Data Flow Controller is malfunctioning or misconfigured).
Perform initialization (factory reset) to restore the factory settings.
If the RUN indicator still does not light up, the Data Flow Controller may be faulty. Replace it.
RUN indicator is not lit (after powering off, powered back on while power continued to be supplied from Power Supply Unit).
Before you cycle the power supply after power OFF, wait a while and confirm that the PWR indicator has turned OFF.
LINK indicator on Ethernet port is not lit.
Make sure that the Ethernet cables are connected correctly.
If there is a problem with a network cable or network device, replace it.
NEWUSB memory device cannot be used (USB ports are disabled).
In the USB port management window of the Web UI, enable the USB ports and restart the Data Flow Controller.
NEWUSB memory device cannot be used (device is not recognized).
Use USB memory devices that comply with the USB standards. Or, use recommended USB memory devices.
Use USB memory devices that are formatted with the FAT32 file system.
Time is incorrect.
Manually set the current time in the date and time setting window of the Web UI.
If an NTP server is available in your environment, enable synchronization with the NTP server.