商品概要
Enclosed Switch, Unidirectional hinge roller lever
在庫/販売状況
2026/06/12 00:00 情報更新| 販売状況 | 販売中 |
|---|---|
| 機種区分 | 標準在庫機種 |
| 在庫状況 | △ |
| 標準価格(税別) | ¥ 3,250 |
詳細情報
定格/性能
情報更新:2025/11/14
| Shape | Enclosed Limit switches |
|---|---|
| Life expectancy | General type |
| Rated frequency | 50/60 Hz |
| Contact form | SPDT |
| Load | General load |
| Ratings | AC | (Inductive load) 10 A at 250 VAC(Inductive load) (Lamp load (NC)) 2.5 A at 250 VAC(Lamp load (NC)) (Lamp load (NO)) 1.25 A at 250 VAC(Lamp load (NO)) (Motor load (NC)) 3 A at 250 VAC(Motor load (NC)) (Motor load (NO)) 1.5 A at 250 VAC(Motor load (NO)) (Resistive load) 10 A at 250 VAC(Resistive load) 1.5 A at 125 VAC 10 A at 125 VAC 10 A at 125 VAC 2.5 A at 125 VAC 3 A at 125 VAC 5 A at 125 VAC |
| Ratings | DC | (Inductive load) 0.03 A at 250 VDC(Inductive load) (Inductive load) 0.05 A at 125 VDC (Inductive load) 5 A at 30 VDC (Inductive load) 6 A at 14 VDC (Lamp load (NC)) 0.2 A at 250 VDC(Lamp load (NC)) (Lamp load (NC)) 0.4 A at 125 VDC (Lamp load (NC)) 3 A at 14 VDC (Lamp load (NC)) 3 A at 30 VDC (Lamp load (NO)) 0.2 A at 250 VDC(Lamp load (NO)) (Lamp load (NO)) 0.4 A at 125 VDC (Lamp load (NO)) 1.5 A at 14 VDC (Lamp load (NO)) 1.5 A at 30 VDC (Motor load (NC)) 0.03 A at 250 VDC(Motor load (NC)) (Motor load (NC)) 0.05 A at 125 VDC (Motor load (NC)) 5 A at 14 VDC (Motor load (NC)) 5 A at 30 VDC (Motor load (NO)) 0.03 A at 250 VDC(Motor load (NO)) (Motor load (NO)) 0.05 A at 125 VDC (Motor load (NO)) 2.5 A at 14 VDC (Motor load (NO)) 2.5 A at 30 VDC (Resistive load) 0.25 A at 250 VDC(Resistive load) (Resistive load) 0.5 A at 125 VDC (Resistive load) 10 A at 14 VDC (Resistive load) 6 A at 30 VDC 1.5 A at 8 VDC 10 A at 8 VDC 2.5 A at 8 VDC 3 A at 8 VDC 5 A at 8 VDC 6 A at 8 VDC |
| Inrush current | 15 A max.(NO) 30 A max.(NC) |
| Ambient temperature (Operating) | -10 to 80 ℃ (with no icing) |
| Ambient humidity (Operating) | 35 to 95% |
| Permissible operating frequency | 120 operations / 1 minute max.(Mechanical) 20 operations / 1 minute max.(Electrical) |
| Contact resistance (Initial value) | 15 mΩ max. (initial value for the built-in switch whentested alone) |
| Insulation resistance | 100 MΩ min. (at 500 VDC) |
| Dielectric strength | 1,000 VAC 50/60 Hz 1 min(Between each terminal of the same polarities) 2,000 VAC 50/60 Hz 1 min(Between each terminal and non-live-metallic part) |
|---|---|
| Endurance | 10 million operations min.(Mechanical) 500,000 operations min.(Electrical) |
| Vibration resistance | 10 to 55 Hz, 1.5 mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position.(Malfunction) |
| Shock resistance | 1,000 m/s2 max.(Destruction) |
| Degree of protection | IP67 |
| Classification of protection against electric shock | Class II |
| Operating Force (OF) | Standard value 3.92 N max. |
| Release Force (RF) | Standard value 0.78 N min. |
| Movement Differential | Standard value 1 mm max. |
| Over-Travel | Standard value 6 mm min. |
| Operating Position | Standard value 53±1.2 mm |
| Free Position | Standard value 59.2 mm max. |
| Durability curve | E00000712316.jpg(Electrical) |
CAD
RoHS/REACH対応状況
情報更新:2026/6/03
EU RoHS
| 対応状況 | 対応予定月 | 非含有証明書 |
|---|---|---|
| 対応済み | ダウンロードはこちら |
中国 RoHS
| 中国 RoHS表 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Pb | Hg | Cd | Cr(VI) | PBBs | PBDEs | DBP | DIBP | BBP | DEHP | 環境保護 使用期限 |
| X | O | O | O | O | O | O | O | O | O | 10 |
- "対応済み"や非含有の記載がされた商品であっても、流通在庫等で未対応品が混在する可能性があります。
- 非含有品が必要な際は、弊社営業部門もしくは販売店へお問い合わせください。
規格認証/適合状況
| LR型式承認 (イギリス 船舶規格) |
DNV型式承認 (ノルウェー 船舶規格) |
BV型式承認 (フランス 船舶規格) |
KR型式承認 (韓国 船舶規格) |
NK型式承認 (日本 船舶規格) |
ABS型式承認 (アメリカ 船舶規格) |
|---|---|---|---|---|---|
| No | No | No | No | No | No |