商品概要

Enclosed Switch, Unidirectional hinge roller lever

在庫/販売状況

2026/06/12 00:00 情報更新
在庫/販売状況 ご利用条件
販売状況 販売中
機種区分 標準在庫機種
在庫状況
標準価格(税別) ¥ 3,250

詳細情報

定格/性能

情報更新:2025/11/14

Shape Enclosed Limit switches
Life expectancy General type
Rated frequency 50/60 Hz
Contact form SPDT
Load General load
Ratings | AC (Inductive load) 10 A at 250 VAC(Inductive load)
(Lamp load (NC)) 2.5 A at 250 VAC(Lamp load (NC))
(Lamp load (NO)) 1.25 A at 250 VAC(Lamp load (NO))
(Motor load (NC)) 3 A at 250 VAC(Motor load (NC))
(Motor load (NO)) 1.5 A at 250 VAC(Motor load (NO))
(Resistive load) 10 A at 250 VAC(Resistive load)
1.5 A at 125 VAC
10 A at 125 VAC
10 A at 125 VAC
2.5 A at 125 VAC
3 A at 125 VAC
5 A at 125 VAC
Ratings | DC (Inductive load) 0.03 A at 250 VDC(Inductive load)
(Inductive load) 0.05 A at 125 VDC
(Inductive load) 5 A at 30 VDC
(Inductive load) 6 A at 14 VDC
(Lamp load (NC)) 0.2 A at 250 VDC(Lamp load (NC))
(Lamp load (NC)) 0.4 A at 125 VDC
(Lamp load (NC)) 3 A at 14 VDC
(Lamp load (NC)) 3 A at 30 VDC
(Lamp load (NO)) 0.2 A at 250 VDC(Lamp load (NO))
(Lamp load (NO)) 0.4 A at 125 VDC
(Lamp load (NO)) 1.5 A at 14 VDC
(Lamp load (NO)) 1.5 A at 30 VDC
(Motor load (NC)) 0.03 A at 250 VDC(Motor load (NC))
(Motor load (NC)) 0.05 A at 125 VDC
(Motor load (NC)) 5 A at 14 VDC
(Motor load (NC)) 5 A at 30 VDC
(Motor load (NO)) 0.03 A at 250 VDC(Motor load (NO))
(Motor load (NO)) 0.05 A at 125 VDC
(Motor load (NO)) 2.5 A at 14 VDC
(Motor load (NO)) 2.5 A at 30 VDC
(Resistive load) 0.25 A at 250 VDC(Resistive load)
(Resistive load) 0.5 A at 125 VDC
(Resistive load) 10 A at 14 VDC
(Resistive load) 6 A at 30 VDC
1.5 A at 8 VDC
10 A at 8 VDC
2.5 A at 8 VDC
3 A at 8 VDC
5 A at 8 VDC
6 A at 8 VDC
Inrush current 15 A max.(NO)
30 A max.(NC)
Ambient temperature (Operating) -10 to 80 ℃ (with no icing)
Ambient humidity (Operating) 35 to 95%
Permissible operating frequency 120 operations / 1 minute max.(Mechanical)
20 operations / 1 minute max.(Electrical)
Contact resistance (Initial value) 15 mΩ max. (initial value for the built-in switch whentested alone)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz 1 min(Between each terminal of the same polarities)
2,000 VAC 50/60 Hz 1 min(Between each terminal and non-live-metallic part)
Endurance 10 million operations min.(Mechanical)
500,000 operations min.(Electrical)
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position.(Malfunction)
Shock resistance 1,000 m/s2 max.(Destruction)
Degree of protection IP67
Classification of protection against electric shock Class II
Operating Force (OF) Standard value 3.92 N max.
Release Force (RF) Standard value 0.78 N min.
Movement Differential Standard value 1 mm max.
Over-Travel Standard value 6 mm min.
Operating Position Standard value 53±1.2 mm
Free Position Standard value 59.2 mm max.
Durability curve E00000712316.jpg(Electrical)

CAD

情報更新:2006/4/1

ログイン/会員登録いただくと、CADデータをダウンロードすることができます。

ログイン/会員登録

ダウンロードデータをご利用いただく前に、以下を必ずお読みください。

ソフトウェアの使用条件

RoHS/REACH対応状況

情報更新:2026/6/03

EU RoHS

対応状況 対応予定月 非含有証明書
対応済み ダウンロードはこちら

中国 RoHS

中国 RoHS表
Pb Hg Cd Cr(VI) PBBs PBDEs DBP DIBP BBP DEHP 環境保護
使用期限
X O O O O O O O O O 10
  • "対応済み"や非含有の記載がされた商品であっても、流通在庫等で未対応品が混在する可能性があります。
  • 非含有品が必要な際は、弊社営業部門もしくは販売店へお問い合わせください。

規格認証/適合状況

UL認証 CSA認証 CEマーキング CCC認証 電波法
Yes Yes Yes Yes N/A
LR型式承認
(イギリス
船舶規格)
DNV型式承認
(ノルウェー
船舶規格)
BV型式承認
(フランス
船舶規格)
KR型式承認
(韓国
船舶規格)
NK型式承認
(日本
船舶規格)
ABS型式承認
(アメリカ
船舶規格)
No No No No No No