商品概要
Latching Relay, DC-switching type, 4 poles, Cased, Plug-in terminal, 125 VDC
在庫/販売状況
2026/06/02 00:00 情報更新| 販売状況 | 販売中 |
|---|---|
| 機種区分 | 標準在庫機種 |
| 在庫状況 | △ |
| 標準価格(税別) | ¥ 11,500 |
詳細情報
定格/性能
情報更新:2025/10/20
| Degree of protection | Closed type (cover) |
|---|---|
| Terminal structure | Plug-in terminal |
| Rated voltage | 125 VDC |
| Operate | 22 mA(125 VDC) |
| Release | 23.5 mA(125 VDC) |
| Coil resistance | 5,350 Ω(Release) 5,800 Ω(Operate) |
| Operate voltage (Set voltage) | 80% max. |
| Release voltage (Reset voltage) | 80% max. |
| Maximum voltage | 110% |
| Operate | Approx. 2.7 W |
| Release | Approx. 2.8 W |
| Rated load | 110 VDC 5 A(Inductive load (L/R = 7 ms)) 110 VDC 5 A(Resistive load) |
| Max. contact voltage | AC | 250 VAC |
| Max. contact voltage | DC | 250 VDC |
| Max. contact current | AC | 5 A |
| Max. contact current | DC | 5 A |
| Max. switching capacity | 20 VA |
| Max. switching capacity | 600 W(Inductive load (L/R = 7 ms)) 700 W(Resistive load) |
| Contact form | DPDT + DPST-NO |
| Contact method | Single |
| Contact material | Ag |
|---|---|
| Contact resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
| Min.set-reset signal width | 100 ms (With rated operating power applied, not including contact bounce) |
| Operating time | 60 ms max. (With rated operating power applied, not including contact bounce) |
| Reset time | 30 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum operating frequency | 1800 time/hour(Mechanical) 1800 time/hour(Rated load) |
| Insulation resistance | 100 MΩ min. (at 500 VDC)(Between coil and contacts) 100 MΩ min. (at 500 VDC)(Between contacts of different polarity) 100 MΩ min. (at 500 VDC)(Between contacts of same polarity) 100 MΩ min. (at 500 VDC)(Between set coil and reset coil) |
| Dielectric strength | 1500 VAC 50/60 Hz 1 min(Between contacts of same polarity) 2000 VAC 50/60 Hz 1 min(Between coil and contacts) 2000 VAC 50/60 Hz 1 min(Between contacts of different polarity) 2000 VAC 50/60 Hz 1 min(Between set coil and reset coil) |
| Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude) |
| Vibration resistance | Malfunction | 10 to 35 to 10 Hz, 0.5 mm single amplitude (1 mm double amplitude) |
| Shock resistance | Destruction | 500 m/s2 |
| Shock resistance | Malfunction | 50 m/s2 |
| Endurance | 2,500,000 operations min. (switching frequency 1,800 operations/h)(Mechanical) 500,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h)(Electrical) |
| Failure rate | 5 VDC 10 mA (failure level: Preference value, Switching frequency: 60 operations per minute) |
| Ambient temperature (Operating) | -10 to 55 ℃ (with no freezing or condensation) |
| Ambient humidity (Operating) | 5 to 85% |
| Weight | Approx. 580 g |
| Mounting method | Socket |
| Applicable socket | 14PFA;PL15 |
CAD
RoHS/REACH対応状況
情報更新:2026/5/20
EU RoHS
| 対応状況 | 対応予定月 | 非含有証明書 |
|---|---|---|
| 対応済み | ダウンロードはこちら |
中国 RoHS
| 中国 RoHS表 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Pb | Hg | Cd | Cr(VI) | PBBs | PBDEs | DBP | DIBP | BBP | DEHP | 環境保護 使用期限 |
| O | O | O | O | O | O | O | O | O | O | e |
- "対応済み"や非含有の記載がされた商品であっても、流通在庫等で未対応品が混在する可能性があります。
- 非含有品が必要な際は、弊社営業部門もしくは販売店へお問い合わせください。
規格認証/適合状況
| LR型式承認 (イギリス 船舶規格) |
DNV型式承認 (ノルウェー 船舶規格) |
BV型式承認 (フランス 船舶規格) |
KR型式承認 (韓国 船舶規格) |
NK型式承認 (日本 船舶規格) |
ABS型式承認 (アメリカ 船舶規格) |
|---|---|---|---|---|---|
| Yes | No | No | No | No | No |