商品概要

画像をクリックすると大きくなります

Power relay, 1 pole, SPST-NO, Single contact, Unsealed, Quick-connect terminal, 24 VAC

Power relay, 1 pole, SPST-NO, Single contact, Unsealed, Quick-connect terminal, 24 VAC

在庫/販売状況

2026/06/22 00:00 情報更新
在庫/販売状況 ご利用条件
販売状況 販売中
機種区分 標準在庫機種
在庫状況
標準価格(税別) オープン価格

詳細情報

定格/性能

情報更新:2025/10/22

Degree of protection Closed type (cover)
Terminal structure Tab terminal
Single stable 37.4 mA(24 V AC 60 Hz)
43.5 mA(24 VAC 50 Hz)
Rated voltage 24 VAC
Coil resistance 253 Ω
Operate voltage (Set voltage) 80% max.
Release voltage (Reset voltage) 30% min.
Maximum voltage 110% (23℃)
Single stable Approx. 0.9 VA(60 Hz)
Rated load 250 VAC 10 A(Resistive load)
250 VAC 7.5 A(Inductive load (cosφ = 0.4))
Rated load 30 VDC 10 A(Resistive load)
30 VDC 5 A(Inductive load (L/R = 7 ms))
Max. contact voltage | AC 380 VAC
Max. contact voltage | DC 125 VDC
Max. contact current | AC 10 A
Max. contact current | DC 10 A
Max. switching capacity 1875 VA(Inductive load (cosφ = 0.4))
2500 VA(Resistive load)
Max. switching capacity 150 W(Inductive load (L/R = 7 ms))
300 W(Resistive load)
Contact form SPST-NO
Contact method Single
Contact material Ag-alloy (Cd free)
Contact resistance 30 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 15 ms max. (With rated operating power applied, not including contact bounce)
Reset time 10 ms max. (With rated operating power applied, not including contact bounce)
Maximum operating frequency 1800 time/hour(Rated load)
18000 time/hour(Mechanical)
Insulation resistance 1000 MΩ min. (at 500 VDC)(Between coil and contacts)
1000 MΩ min. (at 500 VDC)(Between contacts of same polarity)
Dielectric strength 1000 VAC 50/60 Hz 1 min(Between contacts of same polarity)
5000 VAC 50/60 Hz 1 min(Between coil and contacts)
Vibration resistance | Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance | Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance | Destruction 1000 m/s2
Shock resistance | Malfunction 100 m/s2(No energized)
200 m/s2(Energized)
Endurance 10 million operations min. (switching frequency 18,000 operations/h)(Mechanical)
100,000 operations min. (Rated load, switching frequency 1,800 operations/h)(Electrical)
Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -40 to 70 ℃ (with no freezing or condensation)
Ambient humidity (Operating) 5 to 85%
Weight Approx. 20 g
Mounting method Upper bracket mounting

RoHS/REACH対応状況

情報更新:2026/6/17

EU RoHS

対応状況 対応予定月 非含有証明書
対応済み ダウンロードはこちら

中国 RoHS

中国 RoHS表
Pb Hg Cd Cr(VI) PBBs PBDEs DBP DIBP BBP DEHP 環境保護
使用期限
O O O O O O O O O O e
  • "対応済み"や非含有の記載がされた商品であっても、流通在庫等で未対応品が混在する可能性があります。
  • 非含有品が必要な際は、弊社営業部門もしくは販売店へお問い合わせください。

規格認証/適合状況

UL認証 CSA認証 CEマーキング CCC認証 電波法
Yes Yes Yes N/A N/A
LR型式承認
(イギリス
船舶規格)
DNV型式承認
(ノルウェー
船舶規格)
BV型式承認
(フランス
船舶規格)
KR型式承認
(韓国
船舶規格)
NK型式承認
(日本
船舶規格)
ABS型式承認
(アメリカ
船舶規格)
Yes No No No No No