商品概要

画像をクリックすると大きくなります

General-purpose Basic switch, Rated carry current 15 A, Contact gap 0.25 mm (high-sensitivity), Low-force hinge lever

General-purpose Basic switch, Rated carry current 15 A, Contact gap 0.25 mm (high-sensitivity), Low-force hinge lever

在庫/販売状況

2026/06/02 00:00 情報更新
在庫/販売状況 ご利用条件
販売状況 販売中
機種区分 標準在庫機種
在庫状況
標準価格(税別) ¥ 2,050

詳細情報

定格/性能

情報更新:2025/12/16

Sensitivity High sensitivity
Contact form SPDT
Contact configuration Rivet
Contact material Ag
Contact gap (standard value) 0.25 mm
External connection method Screw terminal (M4)
Load General load
Rated carry current 15 A
Ratings | AC 1.25 A at 250 VAC(Lamp load (NO))
1.5 A at 125 VAC(Lamp load (NO))
1.5 A at 250 VAC(Motor load (NO))
10 A at 125 VAC(Inductive load)
10 A at 125 VAC(Resistive load)
10 A at 250 VAC(Inductive load)
10 A at 250 VAC(Resistive load)
2.5 A at 125 VAC(Motor load (NO))
2.5 A at 250 VAC(Lamp load (NC))
3 A at 125 VAC(Lamp load (NC))
3 A at 250 VAC(Motor load (NC))
5 A at 125 VAC(Motor load (NC))
Ratings | DC 0.02 A at 250 VDC(Inductive load)
0.02 A at 250 VDC(Motor load (NC))
0.02 A at 250 VDC(Motor load (NO))
0.03 A at 125 VDC(Inductive load)
0.03 A at 125 VDC(Motor load (NC))
0.03 A at 125 VDC(Motor load (NO))
0.2 A at 250 VDC(Lamp load (NC))
0.2 A at 250 VDC(Lamp load (NO))
0.2 A at 250 VDC(Resistive load)
0.4 A at 125 VDC(Lamp load (NC))
0.4 A at 125 VDC(Lamp load (NO))
0.4 A at 125 VDC(Resistive load)
1 A at 30 VDC(Inductive load)
1 A at 30 VDC(Motor load (NC))
1 A at 30 VDC(Motor load (NO))
1.4 A at 30 VDC(Lamp load (NO))
1.5 A at 14 VDC(Lamp load (NO))
1.5 A at 8 VDC(Lamp load (NO))
10 A at 14 VDC(Inductive load)
15 A at 14 VDC(Resistive load)
15 A at 8 VDC(Inductive load)
15 A at 8 VDC(Resistive load)
2 A at 30 VDC(Lamp load (NC))
2 A at 30 VDC(Resistive load)
2.5 A at 14 VDC(Motor load (NO))
2.5 A at 8 VDC(Motor load (NO))
3 A at 14 VDC(Lamp load (NC))
3 A at 8 VDC(Lamp load (NC))
5 A at 14 VDC(Motor load (NC))
5 A at 8 VDC(Motor load (NC))
Inrush current 15 A max.(NO)
30 A max.(NC)
Ambient temperature (Operating) -25 to 80 ℃ (with no icing)
Ambient humidity (Operating) 35 to 85%
Permissible operating speed 0.01 mm/s to 1 m/s
Permissible operating frequency 20 operations / 1 minute max.(Electrical)
240 operations / 1 minute max.(Mechanical)
Contact resistance (Initial value) 15 mΩ max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC 50/60 Hz 1 min(Between each terminal and non-live-metallic part)
2,000 VAC 50/60 Hz 1 min(Between live-metallic part and ground)
600 VAC 50/60 Hz for 1 min(Between each terminal of the same polarities)
Endurance 10 million operations min.(Mechanical)
500,000 operations min.(Electrical)
Degree of protection IP00
Classification of protection against electric shock Class I
Proof tracking index (PTI) 175
Vibration resistance (Malfunction) 10 to 55 Hz, 1.5 mm double amplitude (Malfunction: 1 ms max.)
Shock resistance 1000 m/s2(Destruction)
Operating Force (OF) Standard value 58.8 N max.
Release Force (RF) Standard value 4.90 N min.
Pre-Travel Reference value 19.8 mm max.
Over-Travel Standard value 10 mm min.
Movement Differential Standard value 12.7 mm max.
Operating Position Standard value 19.8 to 21.4 mm

CAD

情報更新:2006/4/1

ログイン/会員登録いただくと、CADデータをダウンロードすることができます。

ログイン/会員登録

ダウンロードデータをご利用いただく前に、以下を必ずお読みください。

ソフトウェアの使用条件

RoHS/REACH対応状況

情報更新:2026/5/20

EU RoHS

対応状況 対応予定月 非含有証明書
対応済み ダウンロードはこちら

中国 RoHS

中国 RoHS表
Pb Hg Cd Cr(VI) PBBs PBDEs DBP DIBP BBP DEHP 環境保護
使用期限
X O O O O O O O O O 10
  • "対応済み"や非含有の記載がされた商品であっても、流通在庫等で未対応品が混在する可能性があります。
  • 非含有品が必要な際は、弊社営業部門もしくは販売店へお問い合わせください。

規格認証/適合状況

UL認証 CSA認証 CEマーキング CCC認証 電波法
Yes Yes Yes Yes N/A
LR型式承認
(イギリス
船舶規格)
DNV型式承認
(ノルウェー
船舶規格)
BV型式承認
(フランス
船舶規格)
KR型式承認
(韓国
船舶規格)
NK型式承認
(日本
船舶規格)
ABS型式承認
(アメリカ
船舶規格)
No No No No No No